1. Functional features:
·Detection angle: 180 * 360 °, anterior hemisphere
·Detection distance is 7-4m radius (when installed at a height of 2.5-4m)
·Work delay: adjustable from 10 seconds to 12 minutes
·Light controlled illumination: 2~2000LUX adjustable
·High frequency output less than 0.2MW
·Penetrating doors, glass panels, and walls for detection
2. Basic parameters:
·Power supply voltage:+ 24VDC±10%
·Power consumption: Static current: 28mA
·Working environment: Temperature: -10 ℃~45 ℃, Humidity: 10~95%
·Isolation protection: The CAN port has 2500VDC electrical isolation
·CAN baud rate: Communication baud rate can be configured
The range is 20kps-100kbps
·Installation methods: indoor, ceiling mounted, wall mounted
·Installation size: 95 × 41mm
·Specification: Compliant with CAN2.0B specification and ISO/DIS 11898 specification